We know that in the use of geothermal cable there are some items that we need to pay attention to, especially when it is running, so the local heating cable at run time what should we pay attention to the practical work item? Let dongguan hua yu electric products co., LTD., under the detailed analysis for everybody!
A test and operation, geothermal cable to note:
1, geothermal cable running debugging, must be installed by professional personnel responsible for the concrete layer (about 21 days) after natural drying, with normal heating (preferably) before and after the heating season and power supply conditions.
2, debugging should be the control room temperature rising steadily, until meet the design requirements; Debugging time for a week, should guarantee the run 3 hours the first day, after increasing every day, until you reach full load operation.
3, testing should be in strict accordance with the instructions of the thermostat, the user should now concentrate on learning the use function of the thermostat.
4, suggest a year started using phase (a month) temperature at 15 ℃ - 18 ℃, and then according to the need to set temperature.
5, annual heating period before use, should check the thermostat and circuit system is normal, door seal are in good condition.
6, in the geothermal cable run after your new furniture, should consider to avoid local high temperature geothermal cable run time.
7, the temperature of judgment should be in its own effective temperature standard, believe in yourself feeling, to find the most suitable temperature.
WenQing tip: don't adopt the way of completely shut down the thermostat in the heating season, to achieve the goal of "savings" expenses, should be through the use of correct thermostat function to achieve the goal of energy saving.
Second, the geothermal cable installation program:
1, before the installation of electric heat type floor heating, heat to test the nominal resistance of the cable and insulation resistance.
2, laying on the ground of thermal insulation materials, can choose special business geothermal cable insulation board, if the ground humidity is bigger, can be laid a layer of waterproof membrane, the first shop again, thermal insulation material.
3, spread a layer of reflection on the insulation aluminum foil, can have the effect of reflected heat.
4 spread a layer of metal mesh, aluminum foil in the reflection layer, the purpose is to prevent the installation of geothermal cable by the insulation materials and enhance the compressive strength of the ground.
5, according to the design of the heating cable arrangement in advance from the power supply terminal will start heating cable heaters even laid on metal net, and makes a binding, every 250 mm hot cable not overlapping. After the uniformly covered in concrete and cover the geothermal cable, about 20 mm to 30 mm (the thickness of the concrete), and then laid the ground adornment material such as floor tile.
Above is geothermal cable at run time for us to pay attention to some of the items, for geothermal cable, if you still have what not understand place or want to know more about this aspect of the information you can feel free to contact us! We will according to the information you want to know to provide you with more perfect answer and service, welcome to need to pay attention to our column, we are sincerely welcome your calls bearer consulting, thanks for everyone here early, I wish you a happy new you, in the business. http://www.dgdianrexian.com.
|